Atlas Copco Authorized Sales and Service Distributor
Service & Maintenance 6 October 2026

How to Adjust a Compressor Pressure Switch

How to Adjust a Compressor Pressure Switch
For the right pressure setting, first check the unit's technical limits and the switch model. Then isolate the power safely, identify the adjustment mechanism from the manufacturer's documentation and verify the cut-in and cut-out values on a pressure gauge. When adjusting compressor pressure, the differential pressure and the maximum allowable working pressure of the air receiver must also be taken into account. The pressure switch determines at what pressure the compressor starts and at what pressure it stops. This is why setting compressor pressure is not just a matter of choosing the bar value you want. The receiver's allowable working pressure, the switch's adjustment range, the safety valve and the air demand at the point of use must all be assessed together.

What Is a Compressor Pressure Switch and What Does It Do?

A pressure switch senses receiver or system pressure and keeps the compressor running within a set pressure range. When pressure drops to the lower limit, it starts the compressor; when it reaches the upper limit, it stops it or sends a stop signal to the control system. Because of this, pressure control is based on managing a lower and an upper threshold together rather than a single bar value.

The role of the pressure switch in a compressor

The main job of the pressure switch is to decide when the compressor runs according to air consumption. When receiver pressure falls to the lower threshold, the motor starts; when consumption drops and the receiver reaches the upper threshold, the compressor stops. This keeps system pressure within a set range according to demand.

Setting the lower and upper values too close together can make the motor start and stop too often. If the range is too wide, pressure variation at the point of use can increase. For this reason, when setting compressor pressure, the difference between the two thresholds must be considered as well as the upper limit.

What are cut-in and cut-out pressures?

Cut-in is the lower pressure at which the compressor starts again when receiver pressure falls. Cut-out is the upper pressure at which the compressor stops as pressure rises. The difference between the two is called the differential or hysteresis, and it directly affects the switch's operating cycle.

The difference between the cut-in and cut-out values determines the compressor's operating cycle. The higher the cut-in, the higher the receiver pressure at which the compressor starts; the cut-out shows the upper pressure at which it stops. The differential between them should be set so that the motor does not start and stop unnecessarily often. The values chosen must suit the pressure switch's adjustment range, the compressor's maximum working pressure and the air receiver's allowable pressure.

Why Is the Pressure Switch Setting Important?

The pressure switch setting affects how often the motor starts, the pressure at the point of use, energy consumption and the system's safe operating limits. A compressor pressure setting that is too high or too low can cause performance problems and make the receiver and line equipment operate outside their design conditions. For this reason, the setting should be based on the unit's nameplate and the manufacturer's technical data.

How an incorrect pressure setting affects the compressor

A cut-out that is higher than necessary can keep the compressor under load longer to reach the target pressure. High pressure that the system does not need can increase the load on the motor and compressor element. Exceeding the allowable working pressure of the receiver or system components is unacceptable from a safety standpoint.

A differential that is too narrow can also cause frequent start-stop cycling. The motor, contactor and switch contacts are then subjected to more switching cycles. For this reason, the range should be set not just for convenience of use but according to the technical limits of the switch and compressor.

Effect on energy consumption and performance

Compressing air to a higher pressure can make the compressor run longer and use more energy. A compressor pressure setting that is higher than necessary can therefore increase motor load, extend running time and increase the amount of air lost through leaks. Choosing a pressure higher than the system needs can increase energy consumption and operating costs rather than improving performance.

On the other hand, setting the pressure too low can prevent pneumatic equipment from reaching the working pressure it needs. Cylinder movements can slow down, equipment performance can drop and process stability can suffer. The aim is therefore to find the lowest stable system pressure that meets the needs of the critical point of use.

How to Adjust a Compressor Pressure Switch

The general sequence is to confirm the compressor's maximum working pressure and the switch model, isolate the power supply safely, identify the adjustment mechanism from the technical documentation and check the cut-in and cut-out values on a pressure gauge. Because screw directions and adjustment logic vary by model, do not adjust the switch based on a generic diagram without knowing the model.

Taking the compressor out of service safely

Before opening the switch cover, turn off the compressor and isolate the power supply in line with the maintenance procedure. Simply turning off the on/off button on the panel may not be enough for work that involves access to electrical terminals. If work is to be done on pressurized connections, that section should also be depressurized according to the manufacturer's instructions.

The system can then be repressurized to verify the setting. Because electrical power and pressure are both present at this stage, the work should be carried out by competent personnel. Pressure switch manufacturers' documentation also recommends isolating the power before adjustment and verifying the set values with a reliable gauge.

Checking the switch cover and adjustment mechanism

Once the cover is open, confirm from the manufacturer's drawing which is the main pressure spring and which is the differential adjustment. On some switches the main spring changes both thresholds together, while the small spring affects only the differential. Other models may work differently on cut-in or cut-out.

If the switch shows burn marks, loose terminals, a broken spring or mechanical damage, do not proceed with the adjustment. Also check the maximum pressure and electrical rating on the switch label. Rather than compensating for a damaged switch with adjustments, replace it with a technically suitable part.

Setting the cut-in and cut-out pressures

First, determine the target cut-in and cut-out values according to the technical limits of the compressor, receiver and switch. Then check in the manufacturer's documentation which adjustment element changes which value. For example, on some models the upper pressure is set first and then the differential, while on others the main adjustment moves both thresholds together.

Make changes in small steps and observe the actual start and stop pressures after each change. The compressor pressure should never be set close to the level at which the safety valve opens. The safety valve is not a normal pressure control element; it is the last line of protection against overpressure.

Checking pressure values on the gauge

After adjustment, monitor the compressor over several operating cycles. Record on the gauge the pressure at which the motor starts and stops, and compare the results with the target values. Seeing similar results over several cycles makes it easier to judge whether the setting is stable.

If the gauge is faulty, the compressor pressure cannot be set properly. A readable pressure gauge and a suitable safety valve on the air receiver are basic safety requirements. If the gauge sticks, does not return to zero or deviates noticeably from a reference measurement, check the gauge first.

What to Watch Out for When Adjusting the Pressure Switch

The basic limit for the setting is the maximum allowable working pressure of the compressor, the air receiver and the equipment in the compressed air line. The cut-out value chosen must be compatible with the switch's adjustment range and the safety devices. Compressor pressure should never be raised above the design pressure to get more air, and safety devices must never be bypassed under any circumstances.

The compressor's maximum working pressure

Just because a pressure switch can be set to a higher value does not mean the compressor is suitable for running at that pressure. The motor, compressor element, hoses and connections must be used within their specified design limits. Confirm the maximum working pressure from the unit's nameplate and technical manual.

If higher pressure is needed, the system's requirements should be reassessed rather than raising the existing unit's limit. Whether the application really needs higher pressure can be determined by measuring line losses and pressure at the point of use.

Air receiver and system pressure

The air receiver's maximum allowable working pressure is an independent limit that the cut-out value must not exceed. The gauge and safety valve on the receiver must be in working order. OSHA regulations also require air receivers to have a visible pressure gauge and a spring-loaded safety valve.

Also check the pressure ratings of hoses, filters, dryers, regulators and pneumatic equipment. Even if the receiver is rated for higher pressure, a component in the line with a lower pressure rating can set the system limit. Compressor pressure should therefore be set taking the entire distribution network into account.

Setting according to the manufacturer's technical values

Do not go outside the switch's adjustable pressure and differential limits. On two similar-looking switches, the same screw can affect different pressure values. For this reason, rely on the technical documentation of the switch you are actually using rather than generic adjustment directions found online.

If the pressure switch setting has been changed, it is useful to record the old and new cut-in/cut-out values in the maintenance log. This shows in later services why the unit was moved away from its factory settings and allows recurring pressure problems to be assessed more accurately.

How Can You Tell If a Compressor Pressure Switch Is Faulty?

A pressure switch fault can show up as the compressor not stopping when it reaches the target pressure, not starting when pressure drops, or cycling on and off at short intervals. However, air leaks, check valve, contactor or motor problems, or mechanical issues with air production can cause similar symptoms. Before making a new setting, check whether the fault really comes from the switch.

The compressor runs continuously

If the compressor does not stop even after reaching the cut-out pressure, there may be a problem with the switch contacts, the pressure sensing connection or the control circuit. On the other hand, if there is a large air leak, the compressor may run continuously because it never reaches the target pressure. Seeing how high the pressure rises on the gauge helps distinguish between these two situations.

If the pressure keeps rising toward the allowable upper limit, do not keep the unit running. Waiting for the safety valve to open is not a normal way of operating. Stop the system safely and carry out a technical check.

The compressor starts and stops frequently

Short cycling can result from too narrow a difference between cut-in and cut-out. A small air receiver, high and intermittent air consumption, line leaks or a check valve problem can also cause the same symptom. Simply widening the differential is therefore no substitute for a proper diagnosis.

When checking the setting, record the actual start and stop values. If the values are within the manufacturer's limits but the unit still cycles very often, the receiver volume, air consumption profile and leaks should be examined separately.

Pressure does not rise or rises too high

Pressure that does not rise is not always a switch fault. Air leaks, intake restriction, valve or screw element problems, belt problems or air consumption exceeding the compressor's capacity can all prevent the target pressure from being reached. The switch does not produce air; it only gives commands according to the current pressure.

If the motor does not stop even though pressure has exceeded the cut-out value, check the switch, pressure connection, contactor and control circuit. In this case, stop the unit and call in technical service rather than experimenting by changing the compressor pressure setting.

Compressor Maintenance and Technical Support with Yıldırım Soğutma

Yıldırım Soğutma provides support with compressor pressure control, periodic maintenance, fault diagnosis and technical service. In addition to control elements such as the pressure switch and gauge, the compressor's general operating values are examined to help identify the cause of pressure-related problems and plan the necessary technical work.

The importance of pressure checks in compressor maintenance

During Yıldırım Soğutma's maintenance and service work, the compressor's working pressure, start-stop behavior and the condition of its pressure control elements can be assessed. Regular checks help detect frequent cycling, pressure fluctuations and performance problems caused by incorrect settings or faults at an early stage.

If the pressure problem does not come from the switch alone, leaks, filters, the receiver and the demand at the point of use are also included in the assessment. This allows maintenance or service work to be planned around the real source of the problem rather than an unnecessary change of settings.

When should you get support from professional compressor service?

If you cannot verify the manufacturer's values for the compressor pressure switch setting, or cannot tell whether the pressure behavior is caused by a fault or by the setting, you can make use of Yıldırım Soğutma's maintenance and technical service. Contact Yıldırım Soğutma to assess your system's operating conditions and plan the necessary checks.

Frequently Asked Questions

What bar should a compressor pressure switch be set to?

There is no single bar value that applies to all compressors. The cut-in and cut-out values are determined by the compressor's maximum working pressure, the air receiver's allowable pressure, the switch's adjustment range and the facility's air needs. Do not set compressor pressure arbitrarily without knowing the factory values.

Why does a compressor pressure switch keep cutting in?

A narrow cut-in/cut-out range, air leaks, a small receiver or high air consumption over a short time can make the compressor start frequently. A switch fault is also possible, but before changing the setting, check the pressure behavior on the gauge and the air consumption.

Does the pressure switch setting affect compressor performance?

Yes. A setting that is too high can lead to longer running under load and higher energy consumption, while a setting that is too low can cause insufficient pressure at the point of use. The right pressure setting should meet the equipment's needs without running the compressor above its design limits.

What happens if a compressor pressure switch fails?

When the switch fails, the compressor may not start at all, may not stop when it reaches the target pressure, or may start and stop erratically. In particular, if the motor does not stop while pressure keeps rising, the unit should not be used and a technical check should be carried out.

Can the user adjust the pressure switch?

Some models have an adjustment procedure in the manufacturer's documentation, but the work may require access to electrical connections and pressurized equipment. If the switch model, safe energy isolation and technical limits are not known, competent technical service should be used to set the compressor pressure.